Pressure Vacuum Relief Valve from China Suppliers and Factory for Reliable Tank Venting Solutions
Principle of Operation
Stationary Position (Seals)
When the silo (or ash bank) internal pressure is maintained within a selected pressure, the valve cover remains stationary. Since the silo (or ash bank) internal pressure force is applied to the top surface of membrane so that it's closely contact with seat, as a result seal is achieved.
Pressure Release
When the silo pressure rises up to the threshold, the pressure inside overcomes the weight of the valve cover, and lifts the cover from the valve seat. While the air is vented until the silo (or bank) internal pressure drops to the threshold, the cover falls back to its normal position.
Vacuum Release
When internal pressure is below atmospheric pressure, a vacuum is created in the silo (or bank). When the pressure drops to the selected threshold, the vacuum ring is lifted to the cloud position due to atmospheric impact. Air begins entering the bank, until the inner silo vacuum value is less than the threshold, the vacuum ring returns back to its normal position against the membrane.
Product Parameters
| Type | Inlet Diameter (mm) | Standard Permeability | Max Permeability | Temperature (℃) | Weight (kg) | ||
|---|---|---|---|---|---|---|---|
| Pressure | Vacuum | Pressure | Vacuum | ||||
| SFF-508 | 508 | 769 | 220 | 2636 | 880 | ≤80 | 98 |
| SFF-300 | 300 | 2800 | 200 | 10000 | 1200 | ≤80 | 65 |
Outline and Dimensions
Conveying hot materials—such as calcined powder, hot ash, or chemical intermediates—places extreme demands on valve seats, seals, and body materials. Long Jin offers high-temperature pneumatic valves rated for continuous operation up to 450°C, but proper selection depends on precise thermal profiles and cooling requirements. To avoid recommending a valve that exceeds or underperforms your needs, we ask you to share your operating conditions through the inquiry form below. Please provide your maximum and minimum conveying temperatures, normal operating temperature, duration of temperature spikes, and the material being conveyed (including any corrosive off-gases). Also tell us about your actuation preferences (pneumatic, electric, or manual) and desired fail-safe position. Once we receive your details, our thermal engineering team will evaluate the best combination of body material, seat design, and thermal expansion compensation features. We will also advise on whether heat dissipation fins or cooling jackets are necessary. Your high-temperature application is not a place for standard products—let us engineer a valve that remains reliable cycle after cycle. Complete the form to begin.
Frequently Asked Questions
Q
How does a pressure vacuum relief valve maintain a seal under normal operating conditions?
Under normal conditions, the silo's internal pressure is kept within the selected threshold. The pressure force acts on the top surface of the membrane, pressing it firmly against the valve seat to create a reliable seal. The valve cover remains stationary as long as the internal pressure does not exceed the set threshold.
Q
At what point does the pressure relief function activate?
The pressure relief function activates when the internal silo pressure rises above the pre-set threshold. At this point, the internal pressure force overcomes the weight of the valve cover, lifting it off the seat and allowing air to vent. Once the pressure drops back to the threshold level, the cover returns to its normal seated position.
Q
How does the vacuum release mechanism work?
When the internal silo pressure falls below atmospheric pressure, a vacuum condition is created. Once the vacuum reaches the selected threshold, atmospheric pressure lifts the vacuum ring, allowing outside air to enter the silo. The vacuum ring returns to its normal position against the membrane once the internal vacuum value rises above the threshold again.
Q
What are the available inlet diameter sizes for the pressure vacuum relief valve?
The valve is available in two standard inlet diameter sizes: SFF-508 with a 508 mm inlet diameter and SFF-300 with a 300 mm inlet diameter. Each model offers different permeability capacities to suit various silo or ash bank application requirements.
Q
What is the maximum operating temperature for these pressure vacuum relief valves?
Both the SFF-508 and SFF-300 models are rated for operating temperatures up to 80°C under standard conditions. For applications involving higher temperatures—such as conveying calcined powder, hot ash, or chemical intermediates—please consult our engineering team for a high-temperature valve solution rated up to 450°C.
Q
What information should I provide when inquiring about a high-temperature valve application?
When submitting an inquiry for high-temperature applications, please include your maximum and minimum conveying temperatures, normal operating temperature, duration of temperature spikes, material being conveyed (including any corrosive off-gases), actuation preferences (pneumatic, electric, or manual), and the desired fail-safe position. This allows our thermal engineering team to recommend the most suitable valve configuration.