LJ Electric Air Heater - Efficient & Compact Heating Solution
01
| Parameter | Value |
| Type | LJ15-100 |
| Rated Power | 15KW-100KW |
| Input Voltage | 380±5% (Three-phase four-wire) |
| Control Accuracy | Class 0.5 |
| Cold Insulation Resistance | ≥2MΩ |
| Type | Power (KW) | Input Voltage (V) | Inlet Temp (°C) | Rated Flow (m³/min) | Rated Temp (°C) | Inlet Flange (mm) |
| LJ-15 | 15 | 380/220 | -20~+15 | 2.5 | 176~232 | 100 |
| LJ-20 | 20 | 380/220 | -20~+15 | 3.3 | 176~232 | 100 |
| LJ-25 | 25 | 380/220 | -20~+15 | 4.1 | 176~232 | 100 |
| LJ-30 | 30 | 380/220 | -20~+15 | 4.9 | 176~232 | 125 |
| LJ-35 | 35 | 380/220 | -20~+15 | 5.8 | 176~232 | 125 |
| LJ-40 | 40 | 380/220 | -20~+15 | 6.6 | 176~232 | 125 |
| LJ-45 | 45 | 380/220 | -20~+15 | 7.5 | 176~232 | 125 |
| LJ-50 | 50 | 380/220 | -20~+15 | 8.3 | 176~232 | 150 |
| LJ-55 | 55 | 380/220 | -20~+15 | 9.1 | 176~232 | 150 |
| LJ-60 | 60 | 380/220 | -20~+15 | 9.9 | 176~232 | 150 |
| LJ-65 | 65 | 380/220 | -20~+15 | 10.8 | 176~232 | 150 |
| LJ-70 | 70 | 380/220 | -20~+15 | 11.6 | 176~232 | 150 |
| LJ-75 | 75 | 380/220 | -20~+15 | 12.4 | 176~232 | 150 |
| LJ-80 | 80 | 380/220 | -20~+15 | 13.7 | 176~232 | 150 |
| LJ-85 | 85 | 380/220 | -20~+15 | 14.1 | 176~232 | 150 |
| LJ-90 | 90 | 380/220 | -20~+15 | 14.9 | 176~232 | 150 |
| LJ-95 | 95 | 380/220 | -20~+15 | 15.7 | 176~232 | 150 |
| LJ-100 | 100 | 380/220 | -20~+15 | 16.6 | 176~232 | 150 |
Pharmaceutical pneumatic conveying systems demand not only wear resistance but also strict cleanliness, smooth internal surfaces, and no dead legs where product could accumulate. Long Jin’s valves for the pharmaceutical industry are designed with these sanitary requirements in mind, but every drug powder has different flow properties and contamination risks. To ensure we recommend the correct valve finish, seal material, and actuation type, we invite you to share your application details through the inquiry form below. Please tell us about your powder characteristics (hygroscopic or not, particle shape, bulk density), batch size, conveying line pressure, and any clean-in-place (CIP) requirements. If you are subject to FDA, GMP, or other regulatory standards, let us know as well. Our engineers will then propose a valve configuration that minimizes product retention and facilitates easy cleaning. We can also provide documentation on surface roughness and material certifications upon request. Your process is too sensitive for guesswork—fill out the form and let us deliver a valve that meets both your conveying and compliance needs.