Inflatable Dome Valve YDF and QQF Type - Leading China Suppliers and Factory for Thermal Power Systems
Applications
For thermal power plant fly ash handling system (as inlet valve, and discharging valve). Can also be used for mining, paper, chemical, pharmaceutical and other types of conveying dry dust, dust-air mixture or other abrasive media.
Characteristics
1
Flexible Opening & Closing — No Dome Erosion
In the switching process, there is a gap of 0.8 to 1.5mm between the dome and special inflatable seal, so dome doesn't contact with seal when it rotates. When the valve opens, the discharge opening unobstructed circulation, avoiding direct media the scouring to the spool.
2
Excellent Sealing Performance
Dome valve seal with a special inflatable rubber seal. When the dome is in closed position, rubber seals is inflated expanding tightly onto and around the periphery, forming a seal ring with a very reliable, tight seal, which can effectively cut off the flow of the material in the pipe.
3
Selected Materials & Superior Craftsmanship
Dome is the core component; different wear-resistant materials are used to meet different characteristics of use conditions to make products with wear resistance and erosion resistance. Dome's smooth and hard surface ensures that the dome and inflatable seal closely contact, to achieve the optimum configuration of the seal.
4
Automatic Control & Reliable Operation
Pneumatic actuator dome valve uses fully enclosed rotating cylinder. It has reliable performance, large output torque, and can work under harsh working conditions.
Principle of Operation
The dome component closes beneath the seat (seal) when the seal is relaxed (not inflated), allowing a controlled gap between the seat (seal) and the closing member (dome). Material is allowed to pass through or enter the controlled gap if, due to its characteristics, it is pulled into the gap by the action of the dome component moving to its closed position. In the closed position, high pressure air or other gas enters the space between the back of the seal face and the insert ring to cause the seal face to expand onto and around the periphery of the dome component. Material particles are entrapped by the seal against the dome surface, irrespective of particle size or shape. Before opening the valve, the seat is relaxed, and the controlled gap is reestablished before the dome component moves to its open position. The seal is a loose component clamped into place by a spigot piece and external fasteners holding the top plate assembly to the body. The seal is easily removed for inspection.
Main wearing parts of Dome Valve are the inflatable seal and dome.
Main wearing parts of Dome Valve are the inflatable seal and dome.
Product Parameters
| Parameter | Value |
|---|---|
| Type | QQFB150, QQFB200, QQFB300, YDF50–YDF300 |
| Nominal Diameter | DN50–300 |
| Nominal Pressure | 1.0 MPa |
| Actuator Working Pressure | 0.4–0.6 MPa |
| Pressure for Inflatable Seal | 0.15 MPa higher than transporting pressure, using clean, dry, oil-free compressed air (could equip air filter) |
| Applicable Temperature | ≤ 150℃ |
| Applicable Media | Fly ash, ash and slag, dry dust, solid particles, and other abrasive and corrosive materials |
Frequently Asked Questions
Q
What is an inflatable dome valve and how does it work?
An inflatable dome valve is a type of shut-off valve that uses a dome-shaped closing component combined with an inflatable rubber seal. When the dome moves to the closed position, compressed air inflates the seal tightly around the dome periphery, creating a reliable, leak-proof closure. Before reopening, the seal is deflated to create a controlled gap, preventing contact between the dome and seal during rotation.
Q
What industries and applications are dome valves suitable for?
Dome valves are widely used in thermal power plants for fly ash handling systems (as inlet or discharging valves). They are also suitable for mining, paper manufacturing, chemical processing, and pharmaceutical industries — particularly for conveying dry dust, dust-air mixtures, and other abrasive or corrosive media.
Q
What are the available sizes and pressure ratings for the dome valve?
The dome valve is available in nominal diameters from DN50 to DN300, covering types QQFB150, QQFB200, QQFB300, and YDF50–YDF300. The nominal pressure rating is 1.0 MPa, with actuator working pressure in the range of 0.4–0.6 MPa.
Q
What type of compressed air is required for the inflatable seal?
The inflatable seal requires clean, dry, and oil-free compressed air. The supply pressure should be at least 0.15 MPa higher than the transporting pressure. An air filter can be equipped to ensure the air quality meets the required standard.
Q
What are the main wearing parts of the dome valve and how easy are they to replace?
The main wearing parts are the inflatable seal and the dome. The inflatable seal is designed as a loose component clamped in place by a spigot piece and external fasteners, making it easy to remove for inspection or replacement without requiring specialized tools or disassembly of the entire valve body.
Q
What is the maximum operating temperature for the dome valve?
The dome valve is rated for applicable temperatures up to 150℃ (≤150℃), making it suitable for high-temperature industrial environments such as thermal power plant fly ash systems and similar processes involving elevated-temperature abrasive media.