Leave Your Message

Efficient DMC Type Bag Filter for Dust Collection System - Premium China Factory & Trusted Suppliers

The DMC pulse bag filter is expertly designed for efficient dust filtration in various powder banks, effectively filtering dust-laden gases. This product is essential for businesses in China seeking reliable solutions from trusted suppliers and manufacturers. To ensure optimal performance, it's important to consider the dust concentration at the filter's entrance during product selection. The filtration velocity is inversely proportional to the dust and gas concentration, making it crucial to calculate the appropriate filtration area to meet the dust-collecting capability. Generally, the dust collecting capacity should not exceed 400 g/m², which can be determined using the formula: C = G * V * T.

Where:

C: dust collecting ability

G: inlet dust concentration

V: filtration velocity

T: cleaning interval

If results indicate that the dust collecting ability is exceeded, adjustments should be made to both the filtration velocity and the filter area. Choose our DMC pulse bag filter for high-quality, durable solutions directly from a leading factory in China.

    Detail Image

    DMC Type Bag Filter (1)
    DMC Type Bag Filter (2)
    DMC Type Bag Filter (3)
    DMC Type Bag Filter (4)

    Outline and Dimensions

    Code name A B C D H G J L M N I L1 K K1 N-d N1-d1
    DMC24 1410 1450 360 470 2575 3/4" 440 339 1200 370 400 620 110 113 14-Φ11 24-Φ18
    DMC36 1360 1400 755 466 2575 3/4" 441 339 1000 366 400 800 147 113 12-Φ11 24-Φ18
    DMC48 1760 1800 955 890 2575 1 840 339 1200 370 800 1020 110 113 20-Φ10 32-Φ18
    DMC60 2160 2250 1200 866 2600 1 836 336 2000 366 800 1250 120 120 20-Φ11 36-Φ18
    DMC72 2614 2650 1400 870 2600 1 840 339 2400 370 800 1390 120 113 20-Φ11 40-Φ18
    DMC84 3014 3050 1600 1270 2600 1 1240 339 2800 370 1200 1590 120 113 26-Φ11 44-Φ18
    DMC96 3410 3450 1835 1270 2600 1 1240 339 3200 370 1200 1755 124 113 26-Φ11 48-Φ18
    DMC108 3850 3900 2035 1450 2600 1 1400 339 3600 370 1360 120 113 34-Φ11 52-Φ18
    DMC120 4260 4300 2225 1450 2600 1 1240 336 4000 370 1200 124 113 26-Φ11 56-Φ18
    Technical parameters model DMC-24 DMC-36 DMC-48 DMC-60 DMC-72 DMC-84 DMC-96 DMC-108 DMC-120
    Area(m²) 18 27 36 45 54 63 72 81 90
    No. of Bags 24 36 48 6 72 84 96 108 120
    Bag Size Φ120x2000
    Temp(℃) <120
    Pressure(Pa) 1000~1500
    Performance 99%
    Dust Concentration <15(g/m³)
    Filtration Velocity (m/min) 0.5~4
    Air Flow(m³/h) 540~
    4300
    810~
    6480
    1080~
    8640
    1350~
    10800
    1620~
    12900
    1890~
    15100
    2160~
    17200
    2430~
    19400
    2700~
    21600
    Blow Pressure(Mpa) 0.5~0.7
    No. of Meg. Valve(unit) 4 6 8 10 12 14 16 18 20
    Plus Length(m) 0.1~0.2
    Period(s) 60~120
    Interval(s) 1~50
    Power plants rely on consistent, uninterrupted ash handling, and Long Jin’s pneumatic valves have been installed in dozens of coal-fired and biomass facilities across China. However, every plant has unique boiler output, ash characteristics, and conveying line layouts. A valve that performs well in a low-velocity system may fail prematurely in a high-velocity dilute phase setup. To help you avoid costly trial and error, we encourage you to complete the inquiry form with as much detail as possible about your ash handling conditions. Please include your ash type (fly ash, bottom ash, or mixed), moisture content, temperature range, conveying phase (dense or dilute), and current valve failure modes if you are replacing an existing product. If available, share your system’s air-to-material ratio and pipe diameter. Our specialists will cross-reference your data with our past project database and propose a valve model that balances wear resistance, sealing reliability, and lifecycle cost. Don’t let another valve fail mid-cycle—let us engineer one that lasts. Fill out the form below to start the conversation.

    Frequently Asked Questions

    What is the filtration efficiency of DMC series bag filters?
    DMC series pulse bag filters offer a high collection efficiency of up to 99%, suitable for handling inlet dust concentrations below 15 g/m³ across standard industrial environments.
    What is the working temperature limit for standard units?
    The standard operating temperature threshold is below 120℃ (<120℃). For higher temperature conditions, custom filter media and seals are required.
    What are the compressed air pressure requirements for pulse jet cleaning?
    The optimal blowing pressure for pulse jet cleaning ranges between 0.5 and 0.7 MPa, with customizable pulse intervals (1~50s) and cycle periods (60~120s).
    How to determine the right DMC model for your operation?
    Model selection is based primarily on air flow volume (from 540 m³/h up to 21,600 m³/h) and required filtration area (18 m² to 90 m²), matching corresponding bag counts (DMC-24 to DMC-120).
    What information is needed to ensure correct pneumatic valve and filter pairing?
    Key operating details include ash type (fly ash, bottom ash, or mixed), moisture level, process temperatures, conveying phase (dense or dilute), pipe dimensions, and air-to-material ratio.
    What are the standard dimensions for filter bags in this series?
    Across the DMC product family, standard filter bags utilize a uniform specification of Φ120 mm in diameter and 2000 mm in length.

    Make an Free Consultant

    Your Name*

    Phone Number

    Country

    Remarks*

    reset