The DMC pulse bag filter is an efficient solution for filtering dust-laden gas, ideal for a range of powder banks. This advanced system is designed by reputable suppliers and factories in China, ensuring high-quality performance and durability, When selecting the appropriate product type, it’s essential to consider the dust concentration at the entrance. The air flow rate through the filter bag, also known as filtration velocity, is inversely proportional to the concentration of dust and gas. Therefore, determining the filtration area must align with the dust collection capacity, which should not exceed 400 g/m², This dust collecting ability can be calculated using the formula: C = G * V * T, where:, - C represents dust collecting ability, - G is the inlet dust concentration, - V denotes the filtration velocity, and, - T stands for the cleaning interval, To maintain optimal performance, adjustments to filtration velocity and filter area may be necessary if the results exceed the designated dust collecting ability. Trust in our China factory for reliable and effective dust collection solutions

    Detail Image

    DMC Type Bag Filter (1)
    DMC Type Bag Filter (2)
    DMC Type Bag Filter (3)
    DMC Type Bag Filter (4)

    Outline and Dimensions

    Code name A B C D H G J L M N I L1 K K1 N-d N1-d1
    DMC24 1410 1450 360 470 2575 3/4" 440 339 1200 370 400 620 110 113 14-Φ11 24-Φ18
    DMC36 1360 1400 755 466 2575 3/4" 441 339 1000 366 400 800 147 113 12-Φ11 24-Φ18
    DMC48 1760 1800 955 890 2575 1 840 339 1200 370 800 1020 110 113 20-Φ10 32-Φ18
    DMC60 2160 2250 1200 866 2600 1 836 336 2000 366 800 1250 120 120 20-Φ11 36-Φ18
    DMC72 2614 2650 1400 870 2600 1 840 339 2400 370 800 1390 120 113 20-Φ11 40-Φ18
    DMC84 3014 3050 1600 1270 2600 1 1240 339 2800 370 1200 1590 120 113 26-Φ11 44-Φ18
    DMC96 3410 3450 1835 1270 2600 1 1240 339 3200 370 1200 1755 124 113 26-Φ11 48-Φ18
    DMC108 3850 3900 2035 1450 2600 1 1400 339 3600 370 1360 120 113 34-Φ11 52-Φ18
    DMC120 4260 4300 2225 1450 2600 1 1240 336 4000 370 1200 124 113 26-Φ11 56-Φ18
    Technical parameters model DMC-24 DMC-36 DMC-48 DMC-60 DMC-72 DMC-84 DMC-96 DMC-108 DMC-120
    Area(m²) 18 27 36 45 54 63 72 81 90
    No. of Bags 24 36 48 6 72 84 96 108 120
    Bag Size Φ120x2000
    Temp(℃) <120
    Pressure(Pa) 1000~1500
    Performance 99%
    Dust Concentration <15(g/m³)
    Filtration Velocity (m/min) 0.5~4
    Air Flow(m³/h) 540~
    4300
    810~
    6480
    1080~
    8640
    1350~
    10800
    1620~
    12900
    1890~
    15100
    2160~
    17200
    2430~
    19400
    2700~
    21600
    Blow Pressure(Mpa) 0.5~0.7
    No. of Meg. Valve(unit) 4 6 8 10 12 14 16 18 20
    Plus Length(m) 0.1~0.2
    Period(s) 60~120
    Interval(s) 1~50

    Power plants rely on consistent, uninterrupted ash handling, and Long Jin’s pneumatic valves have been installed in dozens of coal-fired and biomass facilities across China. However, every plant has unique boiler output, ash characteristics, and conveying line layouts. A valve that performs well in a low-velocity system may fail prematurely in a high-velocity dilute phase setup. To help you avoid costly trial and error, we encourage you to complete the inquiry form with as much detail as possible about your ash handling conditions. Please include your ash type (fly ash, bottom ash, or mixed), moisture content, temperature range, conveying phase (dense or dilute), and current valve failure modes if you are replacing an existing product. If available, share your system’s air-to-material ratio and pipe diameter. Our specialists will cross-reference your data with our past project database and propose a valve model that balances wear resistance, sealing reliability, and lifecycle cost. Don’t let another valve fail mid-cycle—let us engineer one that lasts. Fill out the form below to start the conversation.

    Frequently Asked Questions

    What is the filtration efficiency of the DMC Type Bag Filter?

    The DMC Type Bag Filter features a high-performance design that delivers a filtration efficiency of 99%, ensuring optimal dust separation and clean air discharge.

    What is the maximum operating temperature range for these bag filters?

    The standard DMC series bag filters are engineered to handle continuous operating temperatures of less than 120℃.

    What information is required to choose the right pneumatic valve?

    To select the best model, you should provide details on your ash type (fly ash, bottom ash, or mixed), moisture content, temperature range, conveying phase (dense or dilute), pipe diameter, and any current valve failure modes.

    What is the air flow range of the DMC Bag Filter series?

    The air flow capacity varies by model size, starting from 540–4,300 m³/h for the DMC-24 model up to 2,700–21,600 m³/h for the largest DMC-120 model.

    What are the standard bag sizes and quantities available?

    The standard bag size for all models in this series is Φ120x2000 mm. The quantity of bags ranges from 24 bags (for the DMC-24) up to 120 bags (for the DMC-120).

    What blow pressure is required for the pulse cleaning system?

    The DMC series pulse jet cleaning system operates efficiently with a blow pressure range between 0.5 to 0.7 Mpa.

    Make an Free Consultant

    Your Name*

    Phone Number

    Country

    Remarks*

    reset