DMC Type Bag Filter for Efficient Dust Collection System - China Suppliers and Factory Solutions
Detail Image
Outline and Dimensions
| Code name | A | B | C | D | H | G | J | L | M | N | I | L1 | K | K1 | N-d | N1-d1 |
| DMC24 | 1410 | 1450 | 360 | 470 | 2575 | 3/4" | 440 | 339 | 1200 | 370 | 400 | 620 | 110 | 113 | 14-Φ11 | 24-Φ18 |
| DMC36 | 1360 | 1400 | 755 | 466 | 2575 | 3/4" | 441 | 339 | 1000 | 366 | 400 | 800 | 147 | 113 | 12-Φ11 | 24-Φ18 |
| DMC48 | 1760 | 1800 | 955 | 890 | 2575 | 1 | 840 | 339 | 1200 | 370 | 800 | 1020 | 110 | 113 | 20-Φ10 | 32-Φ18 |
| DMC60 | 2160 | 2250 | 1200 | 866 | 2600 | 1 | 836 | 336 | 2000 | 366 | 800 | 1250 | 120 | 120 | 20-Φ11 | 36-Φ18 |
| DMC72 | 2614 | 2650 | 1400 | 870 | 2600 | 1 | 840 | 339 | 2400 | 370 | 800 | 1390 | 120 | 113 | 20-Φ11 | 40-Φ18 |
| DMC84 | 3014 | 3050 | 1600 | 1270 | 2600 | 1 | 1240 | 339 | 2800 | 370 | 1200 | 1590 | 120 | 113 | 26-Φ11 | 44-Φ18 |
| DMC96 | 3410 | 3450 | 1835 | 1270 | 2600 | 1 | 1240 | 339 | 3200 | 370 | 1200 | 1755 | 124 | 113 | 26-Φ11 | 48-Φ18 |
| DMC108 | 3850 | 3900 | 2035 | 1450 | 2600 | 1 | 1400 | 339 | 3600 | 370 | 1360 | 120 | 113 | 34-Φ11 | 52-Φ18 | |
| DMC120 | 4260 | 4300 | 2225 | 1450 | 2600 | 1 | 1240 | 336 | 4000 | 370 | 1200 | 124 | 113 | 26-Φ11 | 56-Φ18 |
| Technical parameters model | DMC-24 | DMC-36 | DMC-48 | DMC-60 | DMC-72 | DMC-84 | DMC-96 | DMC-108 | DMC-120 |
| Area(m²) | 18 | 27 | 36 | 45 | 54 | 63 | 72 | 81 | 90 |
| No. of Bags | 24 | 36 | 48 | 6 | 72 | 84 | 96 | 108 | 120 |
| Bag Size | Φ120x2000 | ||||||||
| Temp(℃) | <120 | ||||||||
| Pressure(Pa) | 1000~1500 | ||||||||
| Performance | 99% | ||||||||
| Dust Concentration | <15(g/m³) | ||||||||
| Filtration Velocity (m/min) | 0.5~4 | ||||||||
| Air Flow(m³/h) | 540~ 4300 |
810~ 6480 |
1080~ 8640 |
1350~ 10800 |
1620~ 12900 |
1890~ 15100 |
2160~ 17200 |
2430~ 19400 |
2700~ 21600 |
| Blow Pressure(Mpa) | 0.5~0.7 | ||||||||
| No. of Meg. Valve(unit) | 4 | 6 | 8 | 10 | 12 | 14 | 16 | 18 | 20 |
| Plus Length(m) | 0.1~0.2 | ||||||||
| Period(s) | 60~120 | ||||||||
| Interval(s) | 1~50 | ||||||||
ⓘ
Power plants rely on consistent, uninterrupted ash handling, and Long Jin's pneumatic valves have been installed in dozens of coal-fired and biomass facilities across China. However, every plant has unique boiler output, ash characteristics, and conveying line layouts. A valve that performs well in a low-velocity system may fail prematurely in a high-velocity dilute phase setup. To help you avoid costly trial and error, we encourage you to complete the inquiry form with as much detail as possible about your ash handling conditions. Please include your ash type (fly ash, bottom ash, or mixed), moisture content, temperature range, conveying phase (dense or dilute), and current valve failure modes if you are replacing an existing product. If available, share your system's air-to-material ratio and pipe diameter. Our specialists will cross-reference your data with our past project database and propose a valve model that balances wear resistance, sealing reliability, and lifecycle cost. Don't let another valve fail mid-cycle—let us engineer one that lasts. Fill out the form below to start the conversation.
?
Frequently Asked Questions
-
Q What is the filtration efficiency of the DMC Type Bag Filter?A The DMC Type Bag Filter achieves a filtration performance of 99%, effectively capturing dust particles with a concentration of less than 15 g/m³ from the outlet airstream, making it suitable for demanding industrial dust collection applications.
-
Q What is the maximum operating temperature for the DMC Bag Filter?A The DMC Type Bag Filter is rated for operating temperatures below 120°C. If your process involves higher temperatures, please consult our engineering team to discuss appropriate bag material upgrades or alternative solutions.
-
Q How does the pulse-jet cleaning system work on the DMC Bag Filter?A The DMC Bag Filter uses a pulse-jet cleaning mechanism. Compressed air at 0.5–0.7 MPa is delivered in short pulses (0.1–0.2 m in length) through solenoid valves at programmed intervals (1–50 seconds) and periods (60–120 seconds), dislodging accumulated dust from the filter bags without interrupting the filtration process.
-
Q Which DMC model should I choose based on my required air flow?A Model selection depends on your required air flow (m³/h) and filtration velocity (0.5–4 m/min). For example, DMC-24 handles 540–4,300 m³/h, while DMC-120 covers up to 21,600 m³/h. We recommend sharing your specific process parameters so our specialists can recommend the most suitable model and configuration.
-
Q What bag size and how many filter bags does the DMC series use?A All models in the DMC series use a standard bag size of Φ120×2000 mm. The number of bags ranges from 24 (DMC-24) up to 120 (DMC-120), with each model providing a corresponding filtration area from 18 m² to 90 m².
-
Q Can the DMC Bag Filter be used for fly ash and bottom ash handling in power plants?A Yes. The DMC Type Bag Filter is well-suited for power plant ash handling, including fly ash, bottom ash, and mixed ash types. To ensure optimal performance and valve longevity, we recommend providing detailed system information such as ash type, moisture content, conveying phase, and pipe diameter so our team can engineer the most appropriate solution for your specific conditions.