DMC Pulse Bag Filter for Efficient Dust Collection System - Top China Suppliers & Factory Solutions
Detail Image




Outline and Dimensions
| Code name | A | B | C | D | H | G | J | L | M | N | I | L1 | K | K1 | N-d | N1-d1 |
| DMC24 | 1410 | 1450 | 360 | 470 | 2575 | 3/4" | 440 | 339 | 1200 | 370 | 400 | 620 | 110 | 113 | 14-Φ11 | 24-Φ18 |
| DMC36 | 1360 | 1400 | 755 | 466 | 2575 | 3/4" | 441 | 339 | 1000 | 366 | 400 | 800 | 147 | 113 | 12-Φ11 | 24-Φ18 |
| DMC48 | 1760 | 1800 | 955 | 890 | 2575 | 1 | 840 | 339 | 1200 | 370 | 800 | 1020 | 110 | 113 | 20-Φ10 | 32-Φ18 |
| DMC60 | 2160 | 2250 | 1200 | 866 | 2600 | 1 | 836 | 336 | 2000 | 366 | 800 | 1250 | 120 | 120 | 20-Φ11 | 36-Φ18 |
| DMC72 | 2614 | 2650 | 1400 | 870 | 2600 | 1 | 840 | 339 | 2400 | 370 | 800 | 1390 | 120 | 113 | 20-Φ11 | 40-Φ18 |
| DMC84 | 3014 | 3050 | 1600 | 1270 | 2600 | 1 | 1240 | 339 | 2800 | 370 | 1200 | 1590 | 120 | 113 | 26-Φ11 | 44-Φ18 |
| DMC96 | 3410 | 3450 | 1835 | 1270 | 2600 | 1 | 1240 | 339 | 3200 | 370 | 1200 | 1755 | 124 | 113 | 26-Φ11 | 48-Φ18 |
| DMC108 | 3850 | 3900 | 2035 | 1450 | 2600 | 1 | 1400 | 339 | 3600 | 370 | 1360 | 120 | 113 | 34-Φ11 | 52-Φ18 | |
| DMC120 | 4260 | 4300 | 2225 | 1450 | 2600 | 1 | 1240 | 336 | 4000 | 370 | 1200 | 124 | 113 | 26-Φ11 | 56-Φ18 |
| Technical parameters model | DMC-24 | DMC-36 | DMC-48 | DMC-60 | DMC-72 | DMC-84 | DMC-96 | DMC-108 | DMC-120 |
| Area (m²) | 18 | 27 | 36 | 45 | 54 | 63 | 72 | 81 | 90 |
| No. of Bags | 24 | 36 | 48 | 6 | 72 | 84 | 96 | 108 | 120 |
| Bag Size | Φ120×2000 | ||||||||
| Temp (℃) | <120 | ||||||||
| Pressure (Pa) | 1000~1500 | ||||||||
| Performance | 99% | ||||||||
| Dust Concentration | <15 (g/m³) | ||||||||
| Filtration Velocity (m/min) | 0.5~4 | ||||||||
| Air Flow (m³/h) | 540~ 4300 |
810~ 6480 |
1080~ 8640 |
1350~ 10800 |
1620~ 12900 |
1890~ 15100 |
2160~ 17200 |
2430~ 19400 |
2700~ 21600 |
| Blow Pressure (Mpa) | 0.5~0.7 | ||||||||
| No. of Meg. Valve (unit) | 4 | 6 | 8 | 10 | 12 | 14 | 16 | 18 | 20 |
| Plus Length (m) | 0.1~0.2 | ||||||||
| Period (s) | 60~120 | ||||||||
| Interval (s) | 1~50 | ||||||||
Power plants rely on consistent, uninterrupted ash handling, and Long Jin's pneumatic valves have been installed in dozens of coal-fired and biomass facilities across China. However, every plant has unique boiler output, ash characteristics, and conveying line layouts. A valve that performs well in a low-velocity system may fail prematurely in a high-velocity dilute phase setup. To help you avoid costly trial and error, we encourage you to complete the inquiry form with as much detail as possible about your ash handling conditions. Please include your ash type (fly ash, bottom ash, or mixed), moisture content, temperature range, conveying phase (dense or dilute), and current valve failure modes if you are replacing an existing product. If available, share your system's air-to-material ratio and pipe diameter. Our specialists will cross-reference your data with our past project database and propose a valve model that balances wear resistance, sealing reliability, and lifecycle cost. Don't let another valve fail mid-cycle—let us engineer one that lasts. Fill out the form below to start the conversation.
Frequently Asked Questions
-
Q What is a DMC Type Bag Filter and how does it work?The DMC Type Bag Filter is a pulse-jet fabric filtration system designed to remove dust and particulate matter from industrial exhaust gases. Contaminated air enters the filter housing, passes through cylindrical filter bags (Φ120×2000 mm), and clean air exits through the outlet. Periodically, a high-pressure pulse of compressed air (0.5–0.7 MPa) is injected into each bag row via solenoid valves, dislodging accumulated dust cake into the hopper below for disposal.
-
Q What models are available and how do I choose the right one?DMC Type Bag Filters are available in nine standard models from DMC-24 to DMC-120, with filtration areas ranging from 18 m² to 90 m² and air flow capacities from 540 m³/h up to 21,600 m³/h. Model selection depends primarily on your required air volume, dust concentration (must be <15 g/m³), and available installation space. Refer to the dimensional tables above and contact our technical team with your specific process parameters for a tailored recommendation.
-
Q What operating temperature and pressure can the DMC Bag Filter handle?The DMC Type Bag Filter is designed to operate at gas temperatures below 120°C and system pressures between 1,000 and 1,500 Pa. For applications involving higher temperatures or pressures, please consult our engineering team, as special bag materials or housing modifications may be required to ensure safe and reliable long-term operation.
-
Q What filtration efficiency does the DMC Type Bag Filter achieve?The DMC Type Bag Filter achieves a dust collection efficiency of 99%, making it suitable for applications with strict emission standards. The filtration velocity is adjustable between 0.5 and 4 m/min, allowing operators to optimize the balance between collection efficiency and pressure drop based on actual process conditions and dust load.
-
Q How are the filter bags cleaned, and what compressed air supply is needed?Filter bags are cleaned using an automated pulse-jet system. Solenoid (magnetic) valves — ranging from 4 units on DMC-24 to 20 units on DMC-120 — deliver short compressed air pulses of 0.1–0.2 m in length. The cleaning cycle period is set between 60 and 120 seconds, with an interval of 1–50 seconds between pulses. A compressed air supply of 0.5–0.7 MPa is required for proper cleaning performance.
-
Q Can the DMC Bag Filter be used for ash handling in power plants?Yes. The DMC Type Bag Filter is well-suited for dust collection in coal-fired and biomass power plants, handling fly ash, bottom ash, or mixed ash streams. For optimal valve and system selection, it is important to provide details such as ash type, moisture content, operating temperature, conveying phase (dense or dilute), air-to-material ratio, and pipe diameter. Our specialists will match these parameters to the most appropriate model from our project database.