Dome Valve is a highly regarded rapid opening and closing valve, prominently utilized in thermal power pneumatic ash handling systems, delivering outstanding performance. As one of the leading products from reputable suppliers in China, this valve has been thoroughly tested in the market, establishing itself as a trusted choice among customers. Our factory ensures the highest quality standards, making the Dome Valve an essential component for efficient and reliable operations in various industrial applications. Explore the benefits of partnering with top suppliers in China for your Dome Valve needs

    Applications

    🏭 For thermal power plant fly ash handling system (as inlet valve, and discharging valve). Can also be used for mining, paper, chemical, pharmaceutical and other types of conveying dry dust, dust-air mixture or other abrasive media.

    Characteristics

    🔄
    Flexible Opening & Closing — No Erosion to Dome In the switching process, there is a gap of 0.8 to 1.5mm between the dome and special inflatable seal, so the dome doesn't contact with the seal when it rotates. When the valve opens, the discharge opening allows unobstructed circulation, avoiding direct media scouring to the spool.
    🔒
    Excellent Sealing Performance Dome valve seal uses a special inflatable rubber seal. When the dome is in closed position, the rubber seal is inflated, expanding tightly onto and around the periphery, forming a very reliable, tight seal ring — effectively cutting off the flow of material in the pipe.
    ⚙️
    Selected Materials & Good Craftsmanship The dome is the core component. Different wear-resistant materials are used to meet various use conditions, ensuring wear resistance and erosion resistance. The dome's smooth and hard surface ensures close contact with the inflatable seal, achieving the optimum sealing configuration.
    🤖
    Automatic Control & Reliable Operation The pneumatic actuator dome valve uses a fully enclosed rotating cylinder. It delivers reliable performance, large output torque, and can operate under harsh working conditions with consistent dependability.

    Principle of Operation

    The dome component closes beneath the seat (seal) when the seal is relaxed (not inflated), allowing a controlled gap between the seat (seal) and the closing member (dome). Material is allowed to pass through or enter the controlled gap if, due to its characteristics, it is pulled into the gap by the action of the dome component moving to its closed position. In the closed position, high pressure air or other gas enters the space between the back of the seal face and the insert ring to cause the seal face to expand onto and around the periphery of the dome component. Material particles are entrapped by the seal against the dome surface, irrespective of particle size or shape. Before opening the valve, the seat is relaxed, and the controlled gap is reestablished before the dome component moves to its open position. The seal is a loose component clamped into place by a spigot piece and external fasteners holding the top plate assembly to the body. The seal is easily removed for inspection.

    Main wearing parts of Dome Valve are the inflatable seal and dome.

    Dome Valve Drawing
    Inflatable Dome Valve YDF and QQF type 1
    Inflatable Dome Valve YDF and QQF type 2
    Inflatable Dome Valve YDF and QQF type 3
    Inflatable Dome Valve YDF and QQF type 4

    Product Parameters

    Parameter Value
    Type QQFB150, QQFB200, QQFB300, YDF50–YDF300
    Nominal Diameter DN50–300
    Nominal Pressure 1.0 MPa
    Actuator Working Pressure 0.4–0.6 MPa
    Pressure for Inflatable Seal 0.15 MPa higher than transporting pressure, using clean, dry, oil-free compressed air (can equip air filter)
    Applicable Temperature ≤ 150 ℃
    Applicable Media Fly ash, ash and slag, dry dust, solid particles, and other abrasive and corrosive materials

    Frequently Asked Questions

    ❓ What is an inflatable dome valve and how does it work?
    An inflatable dome valve is a type of shut-off valve where a dome-shaped disc rotates to open or close the flow path. The sealing is achieved by inflating a rubber seal with compressed air, which expands tightly around the dome periphery to create a reliable, leak-proof seal. Before the dome moves, the seal is deflated to create a controlled gap, preventing direct contact and wear.
    ❓ What are the main applications of the YDF / QQF dome valve?
    These dome valves are primarily used in thermal power plant fly ash handling systems as inlet or discharging valves. They are also widely applied in mining, paper, chemical, and pharmaceutical industries for conveying dry dust, dust-air mixtures, and other abrasive or corrosive media.
    ❓ What pressure is required for the inflatable seal to function properly?
    The inflatable seal requires a pressure that is 0.15 MPa higher than the transporting pressure. It must use clean, dry, and oil-free compressed air. An air filter can be equipped to ensure the air quality meets this requirement and to extend seal service life.
    ❓ What are the main wearing parts of the dome valve and how easy is maintenance?
    The main wearing parts of the dome valve are the inflatable seal and the dome itself. The inflatable seal is designed as a loose component clamped into place by a spigot piece and external fasteners, making it very easy to remove for inspection or replacement without requiring specialized tools or disassembly of the entire valve body.
    ❓ What is the maximum operating temperature for these dome valves?
    The YDF and QQF series dome valves are rated for applicable temperatures up to 150 ℃. This makes them suitable for high-temperature fly ash handling and similar industrial processes where elevated temperatures are common.
    ❓ Why does the dome not wear out during the opening and closing process?
    During the switching process, a controlled gap of 0.8 to 1.5 mm is maintained between the dome and the inflatable seal, so there is no direct contact between them when the dome rotates. The seal is only inflated once the dome is fully in the closed position. This design eliminates friction-based wear on both the dome surface and the rubber seal, significantly extending the service life of both components.