Leave Your Message

China LJ Electric Air Heater - Efficient Heating Solution from Reliable Suppliers & Factory

Introducing the LJ Electric Air Heater, an innovative heating solution designed specifically for the ash handling systems in coal-fired power plants. Ideal for applications in delivery chutes and gasification devices, this efficient heater generates heated air to optimize operational performance, Manufactured with precision, our electric heater comprises two main components: the electric heating unit and an advanced control system. The heating element is constructed from OCr27A17M2, while the protective sleeve is made from high-quality 1Cr18Ni9Ti stainless steel seamless pipes. A high-temperature resistance alloy wire, made from crystalline magnesium oxide powder and crafted through a compression molding process, ensures durability and reliability, The control system features state-of-the-art digital circuits, integrated circuit triggers, and high back pressure SCR technology. With an adjustable and constant temperature mechanism, the LJ Electric Air Heater guarantees stable operation and optimal heating efficiency, As a leading China supplier and factory, we are committed to delivering high-quality heating solutions tailored to your needs. Trust the LJ Electric Air Heater for superior performance in your ash handling systems

    Description
    U-shaped structure is replaced by a straight tube for heating element. It is easy installation and maintenance using special wrench. Heating pipe thermal has excellent conductivity and insulation. Electric air heater is synchronized with fan and provides both local control and control interface, when the device encounters sudden shutdown, the control cabinet could help recover automatically and smoothly.
    🔧
    Easy Installation
    Straight tube design with special wrench for quick, simple maintenance.
    âš¡
    Excellent Thermal Conductivity
    Heating pipe delivers superior conductivity and reliable insulation.
    🔄
    Auto Recovery
    Control cabinet enables automatic, smooth recovery after sudden shutdown.
    Detail Image
    LJ Electric Air Heater (1)
    LJ Electric Air Heater (2)
    LJ Electric Air Heater (3)
    Product Parameters
    Parameter Value
    Type LJ15-100
    Rated Power 15KW–100KW
    Input Voltage 380±5% (Three-phase four-wire)
    Control Accuracy Class 0.5
    Cold Insulation Resistance ≥2MΩ
    Type Power (KW) Input Voltage (V) Inlet Temp (°C) Rated Flow (m³/min) Rated Temp (°C) Inlet Flange (mm)
    LJ-15 15 380/220 -20~+15 2.5 176~232 100
    LJ-20 20 380/220 -20~+15 3.3 176~232 100
    LJ-25 25 380/220 -20~+15 4.1 176~232 100
    LJ-30 30 380/220 -20~+15 4.9 176~232 125
    LJ-35 35 380/220 -20~+15 5.8 176~232 125
    LJ-40 40 380/220 -20~+15 6.6 176~232 125
    LJ-45 45 380/220 -20~+15 7.5 176~232 125
    LJ-50 50 380/220 -20~+15 8.3 176~232 150
    LJ-55 55 380/220 -20~+15 9.1 176~232 150
    LJ-60 60 380/220 -20~+15 9.9 176~232 150
    LJ-65 65 380/220 -20~+15 10.8 176~232 150
    LJ-70 70 380/220 -20~+15 11.6 176~232 150
    LJ-75 75 380/220 -20~+15 12.4 176~232 150
    LJ-80 80 380/220 -20~+15 13.7 176~232 150
    LJ-85 85 380/220 -20~+15 14.1 176~232 150
    LJ-90 90 380/220 -20~+15 14.9 176~232 150
    LJ-95 95 380/220 -20~+15 15.7 176~232 150
    LJ-100 100 380/220 -20~+15 16.6 176~232 150
    LJ Electric Air Heater (6)
    Pharmaceutical pneumatic conveying systems demand not only wear resistance but also strict cleanliness, smooth internal surfaces, and no dead legs where product could accumulate. Long Jin's valves for the pharmaceutical industry are designed with these sanitary requirements in mind, but every drug powder has different flow properties and contamination risks. To ensure we recommend the correct valve finish, seal material, and actuation type, we invite you to share your application details through the inquiry form below. Please tell us about your powder characteristics (hygroscopic or not, particle shape, bulk density), batch size, conveying line pressure, and any clean-in-place (CIP) requirements. If you are subject to FDA, GMP, or other regulatory standards, let us know as well. Our engineers will then propose a valve configuration that minimizes product retention and facilitates easy cleaning. We can also provide documentation on surface roughness and material certifications upon request. Your process is too sensitive for guesswork—fill out the form and let us deliver a valve that meets both your conveying and compliance needs.
    Frequently Asked Questions
    Q What is the rated power range of the LJ Electric Air Heater?
    The LJ Electric Air Heater series covers a rated power range from 15KW to 100KW (models LJ-15 through LJ-100), making it suitable for a wide variety of industrial heating applications.
    Q What input voltage does the LJ Electric Air Heater require?
    The heater operates on 380V ±5% three-phase four-wire supply (380/220V), which is the standard industrial power configuration widely used in manufacturing facilities.
    Q How does the straight tube design improve upon the traditional U-shaped structure?
    The straight tube heating element replaces the traditional U-shaped structure, significantly simplifying installation and maintenance. Technicians can use a special wrench for quick servicing, reducing downtime and labor costs.
    Q What happens if the LJ Electric Air Heater experiences a sudden shutdown?
    The integrated control cabinet is designed to handle sudden shutdowns automatically. It detects the interruption and smoothly restores normal operation without manual intervention, minimizing process disruption and protecting the heating elements.
    Q What inlet flange sizes are available for different power models?
    Inlet flange sizes vary by model: LJ-15, LJ-20, and LJ-25 use a 100mm flange; LJ-30 through LJ-45 use a 125mm flange; and LJ-50 through LJ-100 use a 150mm flange, allowing flexible integration into existing duct systems.
    Q Is the LJ Electric Air Heater suitable for pharmaceutical pneumatic conveying systems?
    Yes. Long Jin's equipment is designed with sanitary requirements in mind, including smooth internal surfaces and no product accumulation dead legs. For pharmaceutical applications subject to FDA, GMP, or other regulatory standards, custom valve finishes, seal materials, and actuation types can be configured. Surface roughness documentation and material certifications are available upon request.

    Make an Free Consultant