China LJ Electric Air Heater - Efficient & Compact Heating Solution from Reliable Suppliers and Factory
Description
U-shaped structure is replaced by a straight tube for heating element. It is easy installation and maintenance using special wrench. Heating pipe thermal has excellent conductivity and insulation. Electric air heater is synchronized with fan and provides both local control and control interface, when the device encounters sudden shutdown, the control cabinet could help recover automatically and smoothly.
🔧
Easy Installation & Maintenance with Special Wrench
⚡
Excellent Thermal Conductivity & Insulation
🔄
Synchronized with Fan — Local & Remote Control
🛡️
Auto Recovery After Sudden Shutdown
Detail Image
Product Parameters
| Parameter | Value |
|---|---|
| Type | LJ15-100 |
| Rated Power | 15KW–100KW |
| Input Voltage | 380±5% (Three-phase four-wire) |
| Control Accuracy | Class 0.5 |
| Cold Insulation Resistance | ≥2MΩ |
| Type | Power (KW) | Input Voltage (V) | Inlet Temp (°C) | Rated Flow (m³/min) | Rated Temp (°C) | Inlet Flange (mm) |
|---|---|---|---|---|---|---|
| LJ-15 | 15 | 380/220 | -20~+15 | 2.5 | 176~232 | 100 |
| LJ-20 | 20 | 380/220 | -20~+15 | 3.3 | 176~232 | 100 |
| LJ-25 | 25 | 380/220 | -20~+15 | 4.1 | 176~232 | 100 |
| LJ-30 | 30 | 380/220 | -20~+15 | 4.9 | 176~232 | 125 |
| LJ-35 | 35 | 380/220 | -20~+15 | 5.8 | 176~232 | 125 |
| LJ-40 | 40 | 380/220 | -20~+15 | 6.6 | 176~232 | 125 |
| LJ-45 | 45 | 380/220 | -20~+15 | 7.5 | 176~232 | 125 |
| LJ-50 | 50 | 380/220 | -20~+15 | 8.3 | 176~232 | 150 |
| LJ-55 | 55 | 380/220 | -20~+15 | 9.1 | 176~232 | 150 |
| LJ-60 | 60 | 380/220 | -20~+15 | 9.9 | 176~232 | 150 |
| LJ-65 | 65 | 380/220 | -20~+15 | 10.8 | 176~232 | 150 |
| LJ-70 | 70 | 380/220 | -20~+15 | 11.6 | 176~232 | 150 |
| LJ-75 | 75 | 380/220 | -20~+15 | 12.4 | 176~232 | 150 |
| LJ-80 | 80 | 380/220 | -20~+15 | 13.7 | 176~232 | 150 |
| LJ-85 | 85 | 380/220 | -20~+15 | 14.1 | 176~232 | 150 |
| LJ-90 | 90 | 380/220 | -20~+15 | 14.9 | 176~232 | 150 |
| LJ-95 | 95 | 380/220 | -20~+15 | 15.7 | 176~232 | 150 |
| LJ-100 | 100 | 380/220 | -20~+15 | 16.6 | 176~232 | 150 |
💊
Pharmaceutical pneumatic conveying systems demand not only wear resistance but also strict cleanliness, smooth internal surfaces, and no dead legs where product could accumulate. Long Jin's valves for the pharmaceutical industry are designed with these sanitary requirements in mind, but every drug powder has different flow properties and contamination risks. To ensure we recommend the correct valve finish, seal material, and actuation type, we invite you to share your application details through the inquiry form below. Please tell us about your powder characteristics (hygroscopic or not, particle shape, bulk density), batch size, conveying line pressure, and any clean-in-place (CIP) requirements. If you are subject to FDA, GMP, or other regulatory standards, let us know as well. Our engineers will then propose a valve configuration that minimizes product retention and facilitates easy cleaning. We can also provide documentation on surface roughness and material certifications upon request. Your process is too sensitive for guesswork—fill out the form and let us deliver a valve that meets both your conveying and compliance needs.
Frequently Asked Questions
What is the power range available for the LJ Electric Air Heater?
The LJ Electric Air Heater is available in a wide power range from 15KW to 100KW, covering models LJ-15 through LJ-100, making it suitable for various industrial heating applications with different capacity requirements.
What input voltage does the LJ Electric Air Heater require?
The heater operates on 380V ±5% (three-phase four-wire) input voltage. It also supports 220V configurations depending on the model selected, providing flexibility for different electrical supply conditions.
How does the straight-tube heating element differ from a U-shaped structure?
The straight-tube heating element replaces the traditional U-shaped structure, making installation and maintenance significantly easier. Using a special wrench, technicians can service the unit quickly without complex disassembly, reducing downtime and maintenance costs.
What happens if the electric air heater shuts down unexpectedly?
The LJ Electric Air Heater features a built-in control cabinet that automatically and smoothly recovers the device after a sudden shutdown. This ensures process continuity and minimizes the risk of equipment damage or production interruption.
What inlet flange sizes are available across different models?
Inlet flange sizes vary by model: 100mm flanges are used for LJ-15 to LJ-25, 125mm flanges for LJ-30 to LJ-45, and 150mm flanges for LJ-50 to LJ-100. This allows proper integration with various duct and pipeline sizes.
Can the LJ Electric Air Heater be used in pharmaceutical conveying systems?
Yes. The heater is compatible with pharmaceutical pneumatic conveying systems. For such applications, it is important to specify powder characteristics, batch size, conveying pressure, and any CIP or regulatory requirements (FDA, GMP) so that the correct valve finish, seal material, and actuation type can be recommended.