| Code name | A | B | C | D | H | G | J | L | M | N | I | L1 | K | K1 | N-d | N1-d1 |
| DMC24 | 1410 | 1450 | 360 | 470 | 2575 | 3/4" | 440 | 339 | 1200 | 370 | 400 | 620 | 110 | 113 | 14-Φ11 | 24-Φ18 |
| DMC36 | 1360 | 1400 | 755 | 466 | 2575 | 3/4" | 441 | 339 | 1000 | 366 | 400 | 800 | 147 | 113 | 12-Φ11 | 24-Φ18 |
| DMC48 | 1760 | 1800 | 955 | 890 | 2575 | 1 | 840 | 339 | 1200 | 370 | 800 | 1020 | 110 | 113 | 20-Φ10 | 32-Φ18 |
| DMC60 | 2160 | 2250 | 1200 | 866 | 2600 | 1 | 836 | 336 | 2000 | 366 | 800 | 1250 | 120 | 120 | 20-Φ11 | 36-Φ18 |
| DMC72 | 2614 | 2650 | 1400 | 870 | 2600 | 1 | 840 | 339 | 2400 | 370 | 800 | 1390 | 120 | 113 | 20-Φ11 | 40-Φ18 |
| DMC84 | 3014 | 3050 | 1600 | 1270 | 2600 | 1 | 1240 | 339 | 2800 | 370 | 1200 | 1590 | 120 | 113 | 26-Φ11 | 44-Φ18 |
| DMC96 | 3410 | 3450 | 1835 | 1270 | 2600 | 1 | 1240 | 339 | 3200 | 370 | 1200 | 1755 | 124 | 113 | 26-Φ11 | 48-Φ18 |
| DMC108 | 3850 | 3900 | 2035 | 1450 | 2600 | 1 | 1400 | 339 | 3600 | 370 | 1360 | 120 | 113 | 34-Φ11 | 52-Φ18 | |
| DMC120 | 4260 | 4300 | 2225 | 1450 | 2600 | 1 | 1240 | 336 | 4000 | 370 | 1200 | 124 | 113 | 26-Φ11 | 56-Φ18 |
| Technical parameters model | DMC-24 | DMC-36 | DMC-48 | DMC-60 | DMC-72 | DMC-84 | DMC-96 | DMC-108 | DMC-120 |
| Area (m²) | 18 | 27 | 36 | 45 | 54 | 63 | 72 | 81 | 90 |
| No. of Bags | 24 | 36 | 48 | 6 | 72 | 84 | 96 | 108 | 120 |
| Bag Size | Φ120×2000 | ||||||||
| Temp (℃) | <120 | ||||||||
| Pressure (Pa) | 1000~1500 | ||||||||
| Performance | 99% | ||||||||
| Dust Concentration | <15 (g/m³) | ||||||||
| Filtration Velocity (m/min) | 0.5~4 | ||||||||
| Air Flow (m³/h) | 540~ 4300 |
810~ 6480 |
1080~ 8640 |
1350~ 10800 |
1620~ 12900 |
1890~ 15100 |
2160~ 17200 |
2430~ 19400 |
2700~ 21600 |
| Blow Pressure (Mpa) | 0.5~0.7 | ||||||||
| No. of Meg. Valve (unit) | 4 | 6 | 8 | 10 | 12 | 14 | 16 | 18 | 20 |
| Plus Length (m) | 0.1~0.2 | ||||||||
| Period (s) | 60~120 | ||||||||
| Interval (s) | 1~50 | ||||||||
⚙️
Power plants rely on consistent, uninterrupted ash handling, and Long Jin's pneumatic valves have been installed in dozens of coal-fired and biomass facilities across China. However, every plant has unique boiler output, ash characteristics, and conveying line layouts. A valve that performs well in a low-velocity system may fail prematurely in a high-velocity dilute phase setup. To help you avoid costly trial and error, we encourage you to complete the inquiry form with as much detail as possible about your ash handling conditions. Please include your ash type (fly ash, bottom ash, or mixed), moisture content, temperature range, conveying phase (dense or dilute), and current valve failure modes if you are replacing an existing product. If available, share your system's air-to-material ratio and pipe diameter. Our specialists will cross-reference your data with our past project database and propose a valve model that balances wear resistance, sealing reliability, and lifecycle cost. Don't let another valve fail mid-cycle—let us engineer one that lasts. Fill out the form below to start the conversation.
Frequently Asked Questions
What is a DMC Type Bag Filter and how does it work?
A DMC Type Bag Filter is a pulse-jet dust collector that uses compressed air bursts to clean cylindrical filter bags. Dust-laden air enters the filter chamber, passes through the filter bags, and clean air exits through the outlet. Periodically, a short pulse of compressed air is injected into each bag to dislodge accumulated dust, which falls into the hopper below for collection.
What filtration efficiency does the DMC Bag Filter achieve?
The DMC Type Bag Filter achieves a filtration performance of up to 99%, with outlet dust concentration maintained below 15 g/m³. This makes it suitable for applications in power plants, cement factories, metallurgy, and other industries with strict emission control requirements.
What is the maximum operating temperature for the DMC Bag Filter?
The standard DMC Type Bag Filter is designed for operating temperatures below 120°C. For higher-temperature applications, please consult our engineering team, as customized solutions with heat-resistant filter media and structural modifications may be available.
How do I select the right DMC model for my application?
Model selection depends on several factors including required filtration area (m²), airflow volume (m³/h), dust type and concentration, operating temperature, and available compressed air pressure. Refer to the technical parameters table above to match your airflow requirements to the appropriate DMC model (DMC-24 through DMC-120). Our specialists can also assist with custom sizing based on your specific process conditions.
What compressed air pressure is required to operate the pulse-jet cleaning system?
The DMC Bag Filter's pulse-jet cleaning system requires a compressed air (blow) pressure of 0.5 to 0.7 MPa. The pulse length is set between 0.1 and 0.2 seconds, with a cleaning period of 60 to 120 seconds and an interval of 1 to 50 seconds, all adjustable based on dust load and system requirements.
Can the DMC Bag Filter handle both fly ash and bottom ash applications?
Yes, the DMC Type Bag Filter can be configured for both fly ash and bottom ash handling depending on the model and auxiliary equipment selected. When submitting an inquiry, please specify your ash type, moisture content, particle size distribution, and conveying phase (dense or dilute) so our engineers can recommend the most suitable configuration and filter media for your application.